Hitachi 912E Automatic Chemistry Analyzer
Condition :
Reconditioned and Warrantied
Product Category :
Immunology Analyzers
Our Price :
Rs. 1,402,500
 ask For Quote
 
Product Description :

Roche Hitachi 912E (configured with Ion-Selective Electrodes (ISE))

 

Description:

 

The Roche Hitachi 912 chemistry analyzer is a fully automated chemistry analyzer system designed for small to medium workloads. Instrument operators can expect to conveniently obtain reliable results including standard and special clinical chemistries, homogeneous immunoassays and STAT analyses. This model can also store up to 32 tests on board including 3 Ion-Selective Electrodes (ISE), and perform 360 tests per hour or up to 720 tests with an optional ISE.   Reagents, calibrators and controls interchangeable with other Roche/Hitachi analyzers to minimize inventory, purchasing, and training costs.

 

 Automated sample handling:

70 positions for routine, STAT and QC samples. 2-35 ml sample volumes. Intermix sample types. Intermix 5 ml, 7 ml, 10 ml primary sample tubes and sample cups. No adapters needed.  Refrigerated inner ring for up to 20 standards and controls

 

Method capacity:

68 programmable chemistries, 46 parameter files, 32 methods on-board plus 3 ISEs, reagent bottles in 20 ml, 50 ml, and 100 ml sizes. Operator interaction by touch-screen, mouse or keyboard. Online, software stores 10,000 patient results and 5,000 QC tests. Intuitive software with contest-sensitive help. Processes up to 720 tests per hour from a test menu of greater than 100 assays. Consolidate multiple sample types including serum, plasma, urine and spinal fluid. Bar-coded Reagents: automatic reagent registration, automatic bottle changeover, automatic calibration tracking, random reagent placement.  Monochromatic, bi-chromatic, endpoint and kinetic assay types.

 

 

Sampling rate:

Once every 10 seconds for photometric chemistries, once every 20 seconds for ISE.   Simultaneous double endpoint and double kinetic Photometric & ISE  @  760 tests/hour

 

 

Method Capacity            

Programmable Chemistries         68

Parameter Files                46

Methods On-board         32 plus 3 ISEs

Reagent Bottle Sizes       20, 50, 100 ml

Operator Interaction      Touch-screen

Mouse

Keyboard

Online Software Storage Capacity            10,000 patient results

5,000 QC tests

Consolidated Sample Types       

Serum

Plasma

Urine

Spinal Fluid

Bar-coded Reagents      

Automatic reagent registration

Automatic bottle changeover

Automatic calibration tracking

Random reagent replacement

Sample Volume per Test              3 – 50 µl

Reagent Dispense Volume          25 – 350 ml

Total reaction vol. per test           250 – 500 ml

System Discrete, fully-selective system for Clinical Chemistry, ISE (Na+, K+, Cl–) and Homogeneous

Immunology

Test Throughput 360 tests/hr

720 tests/hr with ISE

Sample Types Serum, Plasma, Urine, CSF, Hemolysate

Sample Input/Output Load/unload capacity: 50 samples on the sample disk

STAT samples are processed with priority, 20 positions on the sample disk

Sample Container Types Primary tubes: 5 to 10ml; 16x100, 16x75, 13x100, 13x75mm

Sample cup: 2.5ml

Micro cup: 1.5ml

Cup on tube: Cup on 16x75/100mm tube

Sample Volume 3 to 50μl

Sample Barcode Types Code 128, Codabar (NW 7), Interleaved 2 of 5, Code 39

Reagents ISE: Na+,K+,Cl–

Onboard capacity: up to 36 tests

Control Unit: Windows based PC

Touch-screen monitor

System Interfaces RS 232 serial interface, bi-directional. Interface to the Service Processor and modem for

Remote Diagnostic Access.

Electrical Requirements 230 Volts AC ±10%, 50 or 60Hz ±0.5%

consumption 1.8KVA

 

Physical Dimensions

Width: 103cm (Disk version)

188cm (Rack version)

Depth: 76cm Height: 117cm

Control unit Width: 60cm Depth: 76cm Height: adjustable

Weight 300kg Analytical Unit

89 kg Control

Certification GS, CE, UL, C-UL

 

Chemistries:

 

Enzymes

Acid Phosphatase

ALP

ALT (GPT)

Amylase-T

Amylase-P

AST (GOT)

CHE

CK

CK-MB

γ-GT

GLDH

HBDH

LDH

Lipase

 

ISE

Chloride

Potassium

Sodium

 

Drugs of Abuse

Amphetamines

Barbiturates

Benzodiaepines

Cannabinoids

Cocaine Metabolite

Ethanol

Methadone

Opiates

Phencyclidine

Propoxyphene

 

Others

Salicylate

T4

T-uptake

 

Therapeutic Drug Monitoring

Carbamazepine

CSA *

Digitoxin

Digoxin

Gentamicin

NAPA

Phenobarbital

Phenytoin

Procainamide

Salicylate

Theophylline

Tobramcyin

Valproic Acid

 

Specific Proteins

%-CDT

α-1-Acid Glycoprotein

α-1-Antitrypsin

α-1-Microglobulin

β-2-Microglobulin

Albumin (Tina-quant)

APO A1

APO B

ASLO

C3c

C4

Ceruloplasmin

CRP

Ferritin

Haptoglobin

HbA1c

Homocysteine *

IgA

IgE

IgG

IgM

Kappa Light Chain

Lamda Light Chain

Lp (a)

Myoglobin

Prealbumin

Rheumatoid Factor

Soluble Transferrin Receptor

Transferrin

 

Substrates

Albumin

Ammonia

Bicarbonate

Bilirubin - direct

Bilirubin - total

Calcium

Cholesterol

HDL Cholesterol Direct

LDL Cholesterol Direct

Creatinine

Fructosamine

Glucose

Iron

Lactate

Magnesium

Phosphorus

Total Protein

U/CSF Protein

Triglycerides

UIBC

Urea / BUN

Uric Acid

 

Enzymes

Acid Phosphatase

Alkaline Phosphatase

ALT / G PT

Amylase - pancreatic

Amylase - total

AST / GOT

Cholinesterase

CK

CK-MB

GGT

GLDH

HBDH

LD-1

LDH

Lipase

 
 ask For Quote
 